Harju maakond, Tallinn, Kesklinna linnaosa, E. Viiralti tn 3/1

Official reportReport last checked Aug 25, 2026.

Identity

Official sourcesChecked Aug 25, 2026Effective Nov 24, 2025

Official addresses

  • Harju maakond, Tallinn, Kesklinna linnaosa, E. Viiralti tn 3/1

Primary use Multi-apartment residential

Official identifiers
  • ads:tunnus 101014578
  • ehr:ehr_code 101014578
  • ads:ads_oid EE00636088

Building facts

Official sourcesChecked Aug 25, 2026Effective Nov 24, 2025

What this building is

5 fields published

  • Name in the registerelamu E. Viiralti tn 3/1
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Building statusExisting
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Primary useOther residential building with three or more apartments
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Use purposeOther residential building with three or more apartments
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Official addressHarju maakond, Tallinn, Kesklinna linnaosa, E. Viiralti tn 3/1
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Dates

1 field published

  • First use1926
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 2 fields this source does not publish
  • Construction startedThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Planned commissioningThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Size and layout

7 fields published

  • Floors above ground5
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Building height23.3 m
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Closed net area1,079.2
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Footprint area246
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Rooms48
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Non-residential units0
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Lifts0
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 2 fields this source does not publish
  • Floors below groundThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Heated areaThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Energy performance

4 fields published

  • Energy classE
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Certificate issuedSep 24, 2017
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Certificate valid untilSep 23, 2027
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Energy certificate1711567/01423
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Heating and electricity

4 fields published

  • Heat supplyLocal heating (building's own heat source)
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Heat sourceBoiler
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Energy carrierNone
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Electrical systemMains (public network)
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 4 fields this source does not publish
  • Heating typeThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Heating systemThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Electricity supplyThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Electric cookerThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Ventilation and cooling

2 fields published

  • VentilationVentilation with heat recovery
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Cooling systemNone
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 1 field this source does not publish
  • Cooling sourceThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Water, sewerage and gas

3 fields published

  • Water supplyMains (public network)
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • SewerageMains (public network)
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Gas supplyNone
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 5 fields this source does not publish
  • Hot waterThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Gas installationThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Household gasThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Washing facilitiesThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • ToiletThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Structure and materials

7 fields published

  • FoundationShallow foundation
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Load-bearing structureBrick
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • External wallBrick
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Facade finishCeramic brick
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Intermediate floorsWood
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Roof structureWood
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
  • Roof coveringRoof tile
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Heritage protection

1 field published

  • Heritage statusBuilding stands on a heritage monument site
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025
Show the 1 field this source does not publish
  • Heritage categoryThis source does not publish this information.
    Official recordChecked Aug 25, 2026Effective Nov 24, 2025

Permit and document timeline

Official sources

Hapito has not imported this yet.

Project parties

Official sources

Hapito has not imported this yet.

Resident experience

Resident evidence

No resident evidence has been published for this building yet.

Eligible resident responses for this building so far: 0. Hapito publishes resident evidence only once enough eligible responses exist under the active policy, so an empty section reflects Hapito's coverage, never the building's condition.

Defects and handling

Resident evidence

No defect threads have been published for this building yet. That reflects what has been published on Hapito, not the building's condition.

Buyer checklist

Derived by Hapito

The buyer checklist turns this report's facts, gaps and conflicts into questions worth asking before you buy. It supports your own investigation and is not legal or engineering advice.

Open the buyer checklist

Request and contribute

Request this report

Asking records one anonymous request signal for this building. It does not change the report content, and nobody can see how many people asked.

Contribute resident experience

Answering the resident survey adds your observations to this building's anonymous resident aggregate once enough eligible responses arrive.

Open the resident survey